Performance Factors For Deepwell Handpumps

 
Sr Characteristics
India Mark II
India Mark III (65mm) VLOM-OTC India Mark III (50mm) VLOM- OTC AFRIDEV Extra Deep well Suction Handpump
1. Minimum Borewell Diameter (mm) 100 125 100 100 100 100
2.

Application Range.

a. Static Water Level (Metres)

b. Optimum Installation Depth (metres)


15-40


21-40


15-25


21-30


15-50


21-60


20-45


20-45


40-90


50-90


3-7


7

3. Stroke length(mm) 125 125 125 225 100 200
4. Discharge/40 strokes litres/minute 15 15 10 16.5 12 40
5. Riser Main

a. Size (mm)

b. Material



32

Galvanised Steel

 



65

Galvanised Steel

 



50

Galvanised Steel /PVC

 


63

UPVC

 



32

Galvanised Steel

 

40


G.I

6. Connecting Rod.
a. Size (mm)

b. Material



12

Steel Zinc Plated/S.S.

 



12

Steel Zinc Plated/S.S.

 



12

Steel Zinc Plated/S.S.

 



10

Steel Zinc Plated/S.S.

 



12

Steel Zinc Plated/S.S.

 

12

Steel Zinc Plated/S.S.

7.
National
/International Standards
IS:9301 IS:13056 & RUWATSANI
NIS - 325
IS:13056 SKAT speci-
fications
/RUWATSAN II WIS-326
IS:13287 IS: 8035
Site Powered by : Infiniti Infosystems